1
/
из
4
No reviews
AngelSounds JPD-100S9 Pregnant Women Home Fetal Doppler Heart Rate Monitor(White)
AngelSounds JPD-100S9 Pregnant Women Home Fetal Doppler Heart Rate Monitor(White)
Обычная цена
$27.88 USD
Обычная цена
Цена со скидкой
$27.88 USD
Цена за единицу
/
за
Стоимость доставки рассчитывается при оформлении заказа.
Не удалось загрузить сведения о доступности самовывоза
1. The product is mainly used to detect the sound of the fetal heartbeat (SFH). Fetal heart rate (FHR) is important basis for checking whether a fetus is healthy. Recording the changes in FHR helps detecting signs of fetal hypoxia, fetal distress, fetal umbilical cord around neck, and so on. Fetal monitoring at home includes listening to fetal heartbeat and checking FHR changes, which help greatly increase fertility safety.
2. It is a hand-held, battery powered audio Doppler device used for detecting fetal heartbeats. The patient is an intended operator.
3. The device is ultrasonic fetal heart beat detector, which can detect the Fetal Heart Rate. The built in speaker of the device allows for listen to the fetal heartbeat. The Product normally is applied to fetus of above 16 weeks growth, difference in pregnant mater. The normal range of fetal heart rate: 110bpm-160bpm
4. Highly sensitive probe, durable
5. Specification:
(1). Battery: 6LR61 9V, Continue working time: more than 4hours
(2). Audio output: Audio Output Power: less than 0.2 W, Audio out socket: 3.5mm
(3). Acoustic working frequency: 2.5MHz+/-5%
(4). Overall sensitivity at the distances 200 mm from the face of the transducer: more than 90dB
(5). Spatial-peak temporal-peak acoustic pressure: less than 1MPa
(6). Output power: less than 20mW
(7). Effective area of the ultrasonic transducer active element: 1.57cm2 +/-15%
(8). The acoustic coupling medium for normal use: ph: 5.5~8
(9). Acoustic impedance: less than 1.7x105g /cm2/s
(10). Suitable gestation: 16 gestational weeks or later
(11).FHR Measuring Range:50bpm -210bpm (beat per minute)
(12). Resolution: 1bpm
(13). Accuracy: +/-2bpm
(14). Operating Conditions: Temperature: 5 to 40 degree Celsius
(15). Size: 119x65x54mm
(16). Weight: 155g(including battery)
2. It is a hand-held, battery powered audio Doppler device used for detecting fetal heartbeats. The patient is an intended operator.
3. The device is ultrasonic fetal heart beat detector, which can detect the Fetal Heart Rate. The built in speaker of the device allows for listen to the fetal heartbeat. The Product normally is applied to fetus of above 16 weeks growth, difference in pregnant mater. The normal range of fetal heart rate: 110bpm-160bpm
4. Highly sensitive probe, durable
5. Specification:
(1). Battery: 6LR61 9V, Continue working time: more than 4hours
(2). Audio output: Audio Output Power: less than 0.2 W, Audio out socket: 3.5mm
(3). Acoustic working frequency: 2.5MHz+/-5%
(4). Overall sensitivity at the distances 200 mm from the face of the transducer: more than 90dB
(5). Spatial-peak temporal-peak acoustic pressure: less than 1MPa
(6). Output power: less than 20mW
(7). Effective area of the ultrasonic transducer active element: 1.57cm2 +/-15%
(8). The acoustic coupling medium for normal use: ph: 5.5~8
(9). Acoustic impedance: less than 1.7x105g /cm2/s
(10). Suitable gestation: 16 gestational weeks or later
(11).FHR Measuring Range:50bpm -210bpm (beat per minute)
(12). Resolution: 1bpm
(13). Accuracy: +/-2bpm
(14). Operating Conditions: Temperature: 5 to 40 degree Celsius
(15). Size: 119x65x54mm
(16). Weight: 155g(including battery)
Specification: